SKYRC D100 V2 AC/DC LIPO 1-6S 10A 100W CHARGER
Description
SKYRC D100v2 is a twin-channel charger with two independent circuits which can charge batteries of varying chemistries (LiPo/LiFe/Lilon/LiHV/NiMH/NiCd/Pb) simultaneously. Capable of operating as a power supply with the maximum output of 100W helps the hobbyists to power other DC equipments. With its unprecedented function of voice guide, even a freshman can operate this charger easily. Additional feature including our "SCAN TO GO" and smart phone control via Bluetooth.
Twin-channel Charger
SKYRC D100v2 allows you to plug 2 batteries into one charger simultaneously, and it will intelligently and automatically charge 2 battries at once to their maximum capacity. To top of it, the batteries being charged do not even need to have the same configuration. You can connect different chemistry (LiPo/LiFe/Lilon/LiHV/NiMH/NiCd/Pb)batteries into any of the charging ports.
Dual Input and Power Distribution
The input of the charger is AC 100-240V and DC 11-18V. In DC mode, the power of each channel is 100W. Total power is 200W. In AC mode, it supports power distribution, between Channel A, Channel B & Power Supply. For example, if both channel A and channel B are set to 40W, then, the DC power is 20W. The total power is 100W. (40W+40W+20W=100W)
Optimized Operating Software
SKYRC D100v2 features the so-called AUTO function that sets the feeding current during the process of charging or discharging. Especially for lithium batteries, it can prevent the overcharging which may lead to an explosion due to the user's fault. It can disconnect the circuit automatically and alarm once detecting any malfunction. All the programs of this product were controlled through two way linkage and communication, to achieve the maximum safety and minimize the trouble. All the settings can be configured by users!
DC Power Output Supported
With the unique feature of DC power source, the user does not have to carry additional big and heavy power supply to the racing track or flying filed.
Voice Guide
Purposes to make the charger more intuitive and user friendly.
Special Features
Battery Memory (Data Store/Load)
The charger can store up to 10 different charge/discharge profiles for each channel. You can keep the data pertaining to program setting of the battery of continuous charging or discharging. Users can call out these data at any time without any special program setting.
Terminal Voltage Control (TVC)
The charger allows user to change the end voltage. (for expert user only)
SkyCharger APP - Smart Phone Control via Bluetooth (both iOS and Android)
The Bluetooth 4.0 connectivity allows the user to remote control and monitor the D100 v2 comfortably through an app on a portable device such as smartphone, iPad, or iPhone. The iOS app can be downloaded from iTunes Store, the Android app from Google Play Store. Operation of the app is self-explanatory and the same on iOS and on Android. Explicit pairing is not required; after download and installation just activate Bluetooth on your mobile device and launch the app. D100 v2 and your device will establish Bluetooth connection automatically.
SCAN TO GO
A very unique feature of D100v2 is SCAN TO GO (automatically charging system). As the range of battery types and capacity becomes more and more, each battery requires its own dedicated charging process. It is easy to set up the charger incorrectly for a specific type of battery, resulting damage the battery or even cause accident.
The revolutionary SCAN TO GO provides a solution to this problem by allowing the user to assign a QR Code which contains all the relevant data for the battery for charging or discharging. The user can create a unique QR Code by using "SkyCharger" apps. Print it and paste it on the battery.
Using your smart phone and launch "SkyCharger" app. Since all the essential information is stored in the QR Code. All you need to do is press the Scan button, and the charge or discharge process will start automatically.
Charge Master - PC Control Software
The free "Charge Master" software gives you unparalleled ability to operate the charger through the computer. You can monitor pack voltage, cell voltage and other data during the charging, view charge data in real-time graphs. And you can initiate, control the charger from "Charge Master". The user can monitor pack voltage, cell voltage and other data during the charging, view charge data in realtime graphs, and can also control charging and update firmware from "Charge Master".
Balancing Individual Cells Battery During Discharging
During the process of discharging, SKYRC D100v2 can monitor and balance each cell of the battery individually. Error message will be indicated and the process will be ended automatically if the voltage of any single one cell is abnormal.
Fast Charge and Storage Mode of Lithium Battery
Function of the two modes differs from each other. "FAST CHG" minimizes battery charge time, while "STORAGE" has the capacity to control the final battery voltage, which is necessary and helpful for a rarely used battery.
Re-Peak Mode of NiMH/NiCd Battery
In re-peak charge mode, the charger can peak charge the battery once, twice or three times in a row automatically. This is good for making the battery fully charged.
Delta-peak Sensitivity for NiMH/NiCd
Delta-peak sensitivity for NiMH/NiCd battery: The automatic charge termination program based on the principle of the Delta-peak voltage detection. When the battery's voltage exceeds the threshold, the process will be terminated automatically.
Cyclic Charging/Discharging
1 to 5 cyclic and continuous process of charge > discharge or discharge > charge is operable for battery refreshing and balancing to stimulate the battery's activity.
Automatic Charging Current Limit
You can set up the upper limit of the charging current when charging your NiMH or NiCd battery, it is useful for the NiMH battery of low impedance and capacity in the 'AUTO' charging mode.
Battery Voltage Meter
The user can check battery's total voltage, the highest voltage, the lowest voltage and each cell's voltage.
Battery Internal Resistance Meter
The user can check battery's total internal resistance and each cell's internal resistance.
Capacity Limit
The charging capacity is always calculated as the charging current multiplied by time. If the charging capacity exceeds the limit, the process will be terminated automatically when you set the maximum value.
Temperature Threshold*
The battery's internal chemical reaction will cause the temperature of the battery to rise. If the temperature limit is reached, the process will be terminated. This function is only available by connecting optional temperature probe, which is not included * in the package.
Processing Time Limit:
You can also limit the maximum process time to avoid any possible defect.
USB Power 5V/2.1A
You can charge your phone and tablet using the built-in USB power output port.
Specs:
- DC Input Voltage: 11-18V
- AC Input Voltage: 100-240V
- Display Type: 128x64 LCD
- Display Backlight: Cool White
- Case Material: Plastic
- Controls: Five Buttons
- Case Size: 153 x 140 x 67 mm
- Weight: 668 g
- DC Power Supply Output: 13.8V / Max. 100W
- PC Communications: USB Port for PC Control & Firmware Upgrade
- External Port: 2-6S Balance Socket-XH, Temperature Probe Socket, Battery Socket, AC/DC Input, DC Output, Micro USB Port for PC, 5V-2.1A USB Output.
- Delta Peak Detection for NiMH/NiCd: 3-15mV/cell / Default: 4mV/cell
- Charge Cut-off Temperature: 20ºC-80ºC (adjustable)
- Charge Voltage: NiMH/NiCd: Delta peak detection
- LiPo: 4.18-4.25V/cell
- LiIon: 4.08-4.2V/cell
- LiFe: 3.58-3.7V/cell
- LiHV: 4.25-4.35V/cell
- Balance Current: 300mA/cell
- Reading Voltage Range: 0.1-26.1V
- Battery Types/Cells: LiPo/LiIon/LiFe/LiHV: 1-6cells
- NiMH/NiCd: 1-15cells
- Pb: 2-20V
- Battery Capacity Range: NiMH/NiCd: 100-50000 mAh
- LiPo/LiIon/LiFe/LiHV: 100-50000 mAh
- Pb: 100-50000 mAh
- Charge Current: 2x 0.1A-10.0A
- Safety Timer: 1-720 minutes / OFF
- Charge Wattage: AC 100W (Support Power Distribution) DC 2x100W
- Discharge Current: 2x 0.1A-2.0A
- Discharge Cut-off Voltage: NiMH/NiCd: 0.1-1.1V/cell
- LiPo: 3.0-3.3V/cell
- LiIon: 2.9-3.2V/cell
- LiFe: 2.6-2.9V/cell
- LiHV: 3.1-3.4V/cell
- Pb: 1.8-2.0V/cell
- Discharge Wattage: 2x 10W
- Balance Cells: 2-6 cells
- Memory: 10x2 Different Charge/Discharge Profiles
- Charge Method: CC/CV for Lithium Types and Lead (Pb) Batteries & Delta-peak Sensitivity for NiMH/NiCd.
Included:
- SKYRC D100v2 Charger
- 2x XH Adaptor
- 2x Charging Cable
- 2x Banana connectors with XT60 connector Charging Cable
- Power Cord